|
|
Anodic inhibitors build a thin protective film along the anode, increasing the potential at the anode and slowing the corrosion reaction. The film is initiated at the anode although it may eventually cover the entire metal surface. Because the film is not visible to the naked eye, the appearance of the metal will be left unchanged. As long as the inhibition is taking place at ther anodes, where metal dissolution takes place, the expected corrosion rates as a function of the inhibitor concentration differs in anodic inhibitors than the cathodic ones.
As the concentration increases, the corrosivity increases, reaches a maximum limit, and afterwards starts to decrease. This maximum value can be even a hundred times higher than the value of the untreated one. As the concentration increases, the corosivity continue to drop, comming asymptotically to the minimum equilibrium value, related to the corrosion inhibitor type and the system's characteristics. The explanation of the phenomenon is that a corosion inhibitor is blocking the anodic sites,where corrosion takes place. The concentration of the inhibitor is below the required levels, and the protective films are not yet established, then the inhibitor start to block weak anodes first. as the stronger (and more active anodes resist to the blockage). As the cathodic potential remains constant and the majority of the strong anodes remains active the blocking of the weak anodes liberates excessive potential to the strong anodes to corrode. Of course as the concentration increases, then the inhibitor can react with the strong anodes, and blocking them the corrosivity is decreased. The final value is finally the one tenth of the
value that a typical cathodic inhibitor can yield. If we are trying to distort the equilibrium, by lowering the inhibitor concentration, as it is presented in the video to the right, at the begining no significant increase of the corrosivity is taking place. As the decrease continious, start to increase the corrosivity, reaches a maximum limit (much higher than the maximum limit achieved when we where increasing the concentration, and then drops sharply to the untreated system's value. Due to this caracteristic performance anodic inhibitors are caracterized as "UNSAFE" and care has to be taken as to:
So the differential aeration cells remain not only untouched, but they are combined to the entire cathodes of the system collecting the sum of the corrosion potential. Their activity is highly accelerated, controlled only from the diffusion of the corrosion products through the porous deposit. As final conclusion, anodic inhibitors are giving an excellent proteciotn to the system, but care should be taken as :
|
|